wire separationequipment
ZJD2008 light electric current ground fault wire separation
equipment is a kind of intelligent monitor equipment installed in
the transformer station, which is used in the single-phase ground
system.Our company apply a new science and method of modern
computer monitor technology, and we have improved greatly in
imitation signal treatment, A/D transformation, calculation
platform and calculating method. We developed a new ZJD2008 control
machine light electric current ground wire separation equipment,
and we finally break through the hard problem of wire separation
accuracy a bit low”, which has troubled some users for a long time.
【Product feature】
1.ZJD2008 light electric current ground fault wire separation
equipment adopts a updated inset control machine as a hardware
platform, ultrapower consumption controller and electron element,
and it can equip IDE and solid electron hardware.The integrated
equipment has an integral whole 6.4 highlight colour liquid crystal
screen, normal internal keyboard and double-key touch mouse, and
two USB joint in the front.
2.The equipment can aplly base-wave group to range and phase, the
fifth power tuning wave,the first half wave, microwave, current
sample and nil-order power separation capacity to separate wires in
general on the ground of light electric current ground wire
separation fields.
3.Take the lead in introducing advanced signal treatment method in
the other field:cruise control and guide TV topography match
technology, preliminarily distinguish and classify the picture in
the fault signal. On the ground of the preliminary distinguishing
result, apply the obscure inference method in the manual
intelligence field to decide the optimum addition-balance
coefficient,and treat the conclusion of different wire separation
methods in order to acquire the most reliable result of wire
separation.
4.Intelligenized auto-examining hardware is adopted a Watchdog
technology.
5.The equipment, a fault wave-record ability with superhuge
capacity, not only can directly analyse the wave, but also the wire
separation through a wave-analysis software equipped randomly in
the machine.
6.The equipment was equipped with normal series connection
communication joint(RS232RS485), and adopts a standard CDT
communication rules and regulations awarded by the Ministry.
7.The model selection is abundant, 8 section base wires can connect
at most, and 56 outlet wires.
【Applying scope】
ZJD2008 light electric current ground fault wire separation
equipment can apply to 3KV-66KV neutral point nonground (or neutral
point passing resistance),the single-phase ground wire separation
of reducing arc coil ground system.This equipment can be used
widely in the system of power supply of transformer station of
electric power system,power station,metallurgy,coal,railway,etc. in
the large-sized plant and mine enterprise.